Vivantis Technologies Sdn Bhd

  • Increase font size
  • Default font size
  • Decrease font size
Home ViPrimePLUS Real-Time Master Mixes AtTaq Real-Time Master Mixes (Hot Start) ViPrimePLUS One Step AtTaq RT-qPCR MasterMix (Hot Start)

ViPrimePLUS One Step AtTaq RT-qPCR MasterMix (Hot Start)

Description
ViPrimePLUS One Step AtTaq RT-qPCR Master Mix is next generation first choice mix designed for fast and easy one step real-time PCR reaction set up. The improved formulation of master mix contains unique thermostable M-MULV enzyme, Hot Start Taq DNA Polymerases as well as MgCl2 and buffer components at optimal concentrations. The M-MULV enzyme has an optimal operating temperature of 55°C, and has a higher affinity for primer template duplexes which allows very rapid processing during RT step. The One Step AtTaq RT-qPCR Master Mix is designed to achieve excellent results in reaction efficiency, correlation coefficient and slope.

ViPrimePLUS One Step AtTaq RT-qPCR Master Mix can be used to amplify any RNA template including mRNA, total RNA and viral sequences. The improved formulation of RT-qPCR master mix can detect extremely low copy number targets very specifically with high efficiency that gives CT values close to the theoretical time of detection. The ViPrimePLUS One Step AtTaq RT-qPCR Master Mix is a complete system for use in one step real-time PCR, the removal of a separate reverse transcription step reduces handling errors as well as the time taken to obtain results. The formation of primer dimers and non-specific products is prevented leading to optimum sensitivity and specificity..

ViPrimePLUS One Step AtTaq RT-qPCR Master Mix has several formulations optimized to be used with most of real-time PCR instruments. The improved sensitivity and consistency of ViPrimePLUS One Step AtTaq RT-qPCR Master Mix in standard cycling conditions gives the industry leading performance in fast cycling conditions.

Applications
All kinds of RNA sample material suited for RT-qPCR amplification can be used.

Features

  • One step real time RT-qPCR reaction set up
  • Equipped with thermostable M-MULV enzyme and Hot Start Taq DNA Polymerases
  • Reliable quantification of extremely low copy number targets
  • Optimal performance for highly sensitive and specific RT-qPCR reaction
  • Compatible with most of the real-time PCR platforms

Component
3 x 0.6ml aliquots of master mix 0.6ml aliquots of “no RT control master mix standard”

Storage
Stable at -20°C up to the expiry date stated. Store all components at -20°C upon arrival. Keep in aliquot to reduce freeze-thaw cycles.

Quality Control
As part of the ISO9001:2008 quality assurance systems, each lot of ViPrimePLUS One Step AtTaq RT-qPCR Master Mix has been tested against predetermined specifications to ensure consistent product quality and highest levels of performance and reliability.

Limitation Of Use
For research use only. Not recommended or intended for diagnosis of disease in humans or animals. Do not use internally or externally in humans or animals.

Instruments
To calibrate a real-time PCR reaction, various formulations of master mixes are available for most of the platforms.

Product Description Compatible Hardware
QLMM03

ViPrimePLUS One Step AtTaq RT-qPCR Master Mix
Analytik Jena qTower series, BioRad iCycler all series, BioRad CFX96 & CFX384, Cepheid SmartCycler®, Eppendorf Mastercycler series, Fluidigm BioMark™, Illumina Eco, MJ Chromo4, Opticon, PCRMax Eco™, Roche lightcycler® series, Qiagen RotorGene, Thermo PikoReal™
QLMM03-LR

ViPrimePLUS One Step AtTaq RT-qPCR Master Mix with Low ROX
Agilent / Stratagene MX MX3000P®, MX3005P®, MX4000®, Applied Biosystems 7500 and 7500 FAST platform, QuantStudio™, ViiA7
QLMM03-R

ViPrimePLUS One Step AtTaq RT-qPCR Master Mix with ROX
Applied Biosystems 7000,7300,7700,7900 and 7900HT FAST platforms, OpenArray PRISM 7000,7700,7900, GeneAmp® 5700, StepOne™, StepOne™ PLUS

Ordering Information

Catalog No Description Pack Size
QLMM03 ViPrimePLUS One Step AtTaq RT-qPCR MasterMix 150 reactions
QLMM03-LR ViPrimePLUS One Step AtTaq RT-qPCR MasterMix with Low ROX 150 reactions
QLMM03-R ViPrimePLUS One Step AtTaq RT-qPCR MasterMix with ROX 150 reactions

Download
Manual

ViPrimePLUS One Step AtTaq RT-qPCR MasterMix
ViPrimePLUS One Step AtTaq RT-qPCR MasterMix with Low ROX
ViPrimePLUS One Step AtTaq RT-qPCR MasterMix with ROX

Download
MSDS
ViPrimePLUS One Step AtTaq RT-qPCR MasterMix

Publication
This Product Has Been Used In:

Attaran, B., Falsafi, T. (2017). Effect of biofilm formation by clinical isolates of Helicobacter pylori on the efflux-mediated resistance to commonly used antibiotics, . World Journal of Gastroenterology, Vol. 23, No. 7. 1163-1170 (2017).

 

DOWNLOAD & RESOURCES

Brochure
MSDS
Video
Promotion

 

ADDITIONAL INFORMATION

ISO Certificate
RE Buffers Activity Chart

Reaching Us

Headquarters

Vivantis Technologies Sdn Bhd
No 3-2, 3rd Floor, N-Tatt Building,
Jalan TP 5, Taman Perindustrian UEP,
47600 Subang Jaya, Selangor


Tel: +603 7886 2682

 

 

ACCOLADES & ACCREDITATION

Acquaint Us

International Distribution/OEM services:

Email: international@vivantechnologies.com

WhatsApp: +6012 793 0184


Local Distribution/Sales Inquiries:

Email: info@vivantechnologies.com

WhatsApp: +6016 216 0492


Product Technical Support:

vivalab@vivantechnologies.com


General Enquiries:

info@vivantechnologies.com

 

SOCIAL MEDIA