HinfI

Concentration
10-30u/μl

5'…G↓ANTC…3'
3'…CTNA↑G…5'

Reaction Conditions
1X Buffer V3

50mM Tris-HCl (pH 7.5 at 30°C), 10mM MgCl2, 100mM NaCl and 100μg/ml BSA. Incubate at 37°C.

Storage Buffer
10mM Tris-HCl (pH 7.5), 50mM NaCl, 0.1mM EDTA, 1mM DTT, 200μg/ml BSA and 50% glycerol. Store at -20°C.

Thermal Inactivation
80°C for 20 minutes.

Ligation / Recutting Assay
After 20-fold overdigestion with HinfI, more than 90% of the DNA fragments can be ligated and recut.

Overdigestion Assay
An unaltered banding pattern was observed after 1μg of DNA was digested with 30u of HinfI for 16 hours at 37°C.

Supplied with 10X Buffer V3, 10X Buffer UB and Viva Buffer A. (Diluent)

Ordering Information

Catalog No Description Pack Size
RE1278 HinfI 1000u

 

Downloads

Manual

HinfI

 

DOWNLOAD & RESOURCES

Brochure
MSDS
Video
Promotion

 

ADDITIONAL INFORMATION

ISO Certificate
RE Buffers Activity Chart

Reaching Us

Headquarters

Vivantis Technologies Sdn Bhd

Revongen Corporation Center,

Level 17, Top Glove Tower,

No. 16, Persiaran Setia Dagang,

Setia Alam, Seksyen U13,

40170 Shah Alam,

Selangor Darul Ehsan,

Malaysia.


Tel: +603-3359 1166

Fax: +603-3358 0303

 

 

ACCOLADES & ACCREDITATION

Acquaint Us

International Distribution/OEM services:

Email: international@vivantechnologies.com

WhatsApp: +6012 793 0184


Local Distribution/Sales Inquiries:

Email: info@vivantechnologies.com

WhatsApp: +6016 216 0492


Product Technical Support:

vivalab@vivantechnologies.com


General Enquiries:

info@vivantechnologies.com

 

SOCIAL MEDIA