Vivantis Technologies Sdn Bhd

  • Increase font size
  • Default font size
  • Decrease font size
Home ViPrimePLUS Real-Time PCR Kits Human Infection qPCR/RT-qPCR Kits Virus ViPrimePLUS Human T-lymphotropic Virus 2 RT-qPCR Kit

ViPrimePLUS Human T-lymphotropic Virus 2 RT-qPCR Kit

Description
The ViPrimePLUS Human T-lymphotropic Virus 2 RT-qPCR Kit is a Taqman probe-based real-time PCR assay for the detection of Human T-lymphotropic Virus 2 genome in clinical samples (e.g. serum blood).

Human T-Lymphotropic virus (HTLV) is a RNA retrovirus that predominantly affects the T lymphocytes in human. The Human Immunodeficiency virus (HIV) was once categorized in the HTLV genus before the reclassification in 1983. After 30 years from the initial discovery, 4 types of HTLV have been identified and among them, the most significant two are the HTLV 1 and 2, which have affected about 15-20million people worldwide. HTLV-1 is divided into 6 subclasses which are endemic to different regions. It causes multiple disorders such as the often fatal leukaemia, debilitative myelopathy, uveitis and dermatitis. However, HTLV-2, which consists of 4 subtypes, is associated with milder neurological disorder and chronic pulmonary infections. The novel HTLV-3 and HTLV-4 have been isolated in a few cases but they have little clinical significance. Mode of transmission is via breast milk, sexual contact and intravenous drug abuse.

ViPrimePLUS Human T-lymphotropic Virus 2 RT-qPCR Kit is intended for research use only.

Kit Component

  • HTLV2 Primers and Probe Mix (HTLV2 PPM)
  • Positive Control
  • Internal Extraction Control Primers and Probe Mix (IEC PPM)
  • Internal Extraction Control (IEC DNA)
  • Nuclease Free Water
  • Template Preparation Buffer

Product Specification

Technology Taqman probe-based real-time PCR assay
Type of Nucleic Acid Kit RNA
Kit Storage Shipped in room temperature, store at -20℃ on arrival
Sample Material Clinical samples (e.g. serum blood)
Gene Target Polymerase gene (Pol)
Detection Limit 10 to <100 copies per reaction
Sensitivity & Specificity Ct value 28±3 with probability of 95%
Controls Included • Internal Extraction Control (IEC) as inhibition control
• Positive control
Channels • FAM channels detect pathogen amplicons
• VIC/HEX channel detects IEC amplicons

Ordering Information

Catalog No Description Pack Size
QM5058 ViPrimePLUS Human T-lymphotropic Virus 2 RT-qPCR Kit 150 reactions

Download
Manual

ViPrimePLUS Human T-lymphotropic Virus 2 RT-qPCR Kit

 

DOWNLOAD & RESOURCES

Brochure
MSDS
Video
Promotion

 

ADDITIONAL INFORMATION

ISO Certificate
RE Buffers Activity Chart

Reaching Us

Headquarters

Vivantis Technologies Sdn Bhd

Revongen Corporation Center,

Level 17, Top Glove Tower,

No. 16, Persiaran Setia Dagang,

Setia Alam, Seksyen U13,

40170 Shah Alam,

Selangor Darul Ehsan,

Malaysia.


Tel: +603-3359 1166

Fax: +603-3358 0303

 

 

ACCOLADES & ACCREDITATION

Acquaint Us

International Distribution/OEM services:

Email: international@vivantechnologies.com

WhatsApp: +6012 793 0184


Local Distribution/Sales Inquiries:

Email: info@vivantechnologies.com

WhatsApp: +6016 216 0492


Product Technical Support:

vivalab@vivantechnologies.com


General Enquiries:

info@vivantechnologies.com

 

SOCIAL MEDIA