ViPrimePLUS Chlamydophila pneumoniae qPCR Kit

Description
The ViPrimePLUS Chlamydophila pneumoniae qPCR Kit is a Taqman probe-based real-time PCR assay for the detection of Chlamydophila pneumoniae genomes in clinical samples (e.g. respiratory fluids and swabs).

Chlamydophila pneumoniae is a Gram negative, obligated intracellular bacterium which infects the mucosal membrane of the respiratory tract, causing atypical pneumonia, bronchitis, sinusitis, laryngitis and pharyngitis. It is an atypical pathogen that causes 10-20% of the community-acquired pneumonia cases in adults. Risk of infection in males is higher than females, which is probably attributed to smoking. An elderly person may suffer more severe complications from the infection than youths. Incubation period of the infections is 3-4 weeks with gradual onset, from milder upper respiratory tract symptoms, such as persistent coughing, malaise and fever, to more serious pneumonia and bronchitis development. Detection with real time PCR provides real and accurate diagnosis of the source of infection.

ViPrimePLUS Chlamydophila pneumoniae qPCR Kit is intended for research use only.

Kit Component

  • C. pneumoniae Primers and Probe Mix (C. pneumoniae PPM)
  • Positive Control
  • Internal Extraction Control Primers and Probe Mix (IEC PPM)
  • Internal Extraction Control (IEC DNA)
  • Nuclease Free Water
  • Template Preparation Buffer

Product Specification

Technology Taqman probe-based real-time PCR assay
Type of Nucleic Acid Kit DNA
Kit Storage Shipped in room temperature, store at -20℃ on arrival
Sample Material Cinical samples (e.g. respiratory fluids and swabs)
Gene Target Major outer membrane protein (MOMP) gene
Detection Limit 10 to <100 copies per reaction
Sensitivity & Specificity Ct value 28±3 with probability of 95%
Controls Included • Internal Extraction Control (IEC) as inhibition control
• Positive control
Channels • FAM channels detect pathogen amplicons
• VIC/HEX channel detects IEC amplicons

Ordering Information

Catalog No Description Pack Size
QM2013 ViPrimePLUS Chlamydophila pneumoniae qPCR Kit 150 reactions

Download
Manual

ViPrimePLUS Chlamydophila pneumoniae qPCR Kit

 

DOWNLOAD & RESOURCES

Brochure
MSDS
Video
Promotion

 

ADDITIONAL INFORMATION

ISO Certificate
RE Buffers Activity Chart

Reaching Us

Headquarters

Vivantis Technologies Sdn Bhd

Revongen Corporation Center,

Level 17, Top Glove Tower,

No. 16, Persiaran Setia Dagang,

Setia Alam, Seksyen U13,

40170 Shah Alam,

Selangor Darul Ehsan,

Malaysia.


Tel: +603-3359 1166

Fax: +603-3358 0303

 

 

ACCOLADES & ACCREDITATION

Acquaint Us

International Distribution/OEM services:

Email: international@vivantechnologies.com

WhatsApp: +6012 793 0184


Local Distribution/Sales Inquiries:

Email: info@vivantechnologies.com

WhatsApp: +6016 216 0492


Product Technical Support:

vivalab@vivantechnologies.com


General Enquiries:

info@vivantechnologies.com

 

SOCIAL MEDIA