Vivantis Technologies Sdn Bhd

  • Increase font size
  • Default font size
  • Decrease font size
Home ViPrimePLUS Real-Time PCR Kits Human Infection qPCR/RT-qPCR Kits Bacterial ViPrimePLUS Staphylococcus epidermidis qPCR Kit

ViPrimePLUS Staphylococcus epidermidis qPCR Kit

Description
The ViPrimePLUS Staphylococcus epidermidis qPCR Kit is a Taqman probe-based real-time PCR assay for the detection of Staphylococcus epidermidis genomes in clinical swab samples of the skin, wound and medical equipment.

Staphylococcus epidermidis is a Gram positive, cocci bacterium. This skin colonizer is a commonly known commensal that is also believed to provide protection to the host skin from being colonized by more virulent pathogens. However in recent years, it is also seen as opportunistic pathogen, especially in nosocomial infections. The ability of the pathogenic strains to form biofilm on inert objects, contributes to its major representation in the frequent causative agent involved with infections of indwelling medical devices, such as peripheral or central intravenous catheters (CVCs). The infection is usually introduced from the skin of the patient during device insertion. Second to S. aureus, S. epidermidis is responsible for many bloodstream infection, central nervous system infection, urinary tract infection, eye infection and endocarditis. Due to the increasing antibiotic resistance as a result of continuous exposure, treatment for the patients has remained a challenge.

ViPrimePLUS Staphylococcus epidermidis qPCR Kit is intended for research use only.

Kit Component

  • S. epidermidis Primers and Probe Mix (S. epidermidis PPM)
  • Positive Control
  • Internal Extraction Control Primers and Probe Mix (IEC PPM)
  • Internal Extraction Control (IEC DNA)
  • Nuclease Free Water
  • Template Preparation Buffer

Product Specification

Technology Taqman probe-based real-time PCR assay
Type of Nucleic Acid Kit DNA
Kit Storage Shipped in room temperature, store at -20℃ on arrival
Sample Material Clinical samples (e.g. skin, wound and medical equipment)
Gene Target sodA gene
Detection Limit 10 to <100 copies per reaction
Sensitivity & Specificity Ct value 28±3 with probability of 95%
Controls Included • Internal Extraction Control (IEC) as inhibition control
• Positive control
Channels • FAM channels detect pathogen amplicons
• VIC/HEX channel detects IEC amplicons

Ordering Information

Catalog No Description Pack Size
QM2056 ViPrimePLUS Staphylococcus epidermidis qPCR Kit 150 reactions

Download
Manual

ViPrimePLUS Staphylococcus epidermidis qPCR Kit

 

DOWNLOAD & RESOURCES

Brochure
MSDS
Video
Promotion

 

ADDITIONAL INFORMATION

ISO Certificate
RE Buffers Activity Chart

Reaching Us

Headquarters

Vivantis Technologies Sdn Bhd

Revongen Corporation Center,

Level 17, Top Glove Tower,

No. 16, Persiaran Setia Dagang,

Setia Alam, Seksyen U13,

40170 Shah Alam,

Selangor Darul Ehsan,

Malaysia.


Tel: +603-3359 1166

Fax: +603-3358 0303

 

 

ACCOLADES & ACCREDITATION

Acquaint Us

International Distribution/OEM services:

Email: international@vivantechnologies.com

WhatsApp: +6012 793 0184


Local Distribution/Sales Inquiries:

Email: info@vivantechnologies.com

WhatsApp: +6016 216 0492


Product Technical Support:

vivalab@vivantechnologies.com


General Enquiries:

info@vivantechnologies.com

 

SOCIAL MEDIA