Vivantis Technologies Sdn Bhd

  • Increase font size
  • Default font size
  • Decrease font size

ViPrimePLUS Porcine Circovirus 2 qPCR Kit

Description
The ViPrimePLUS Porcine Circovirus 2 qPCR Kit is a Taqman probe-based real-time PCR assay for the detection of Porcine Circovirus 2 genome in blood and tissues.

Porcine Circovirus (PCV) is a very small circular DNA virus that widely infects pigs. They are classified into PCV1 and PCV2, which differ in the ORF2 region that encodes for Cap. PCV1 was first discovered as a contaminant in a pig kidney cell line and it is a commonly present swine virus which has no known disease caused. Infection with PCV2 may cause typical PCVD lesions. Some PCV2 infected pigs may also develop the PCV-associated diseases (PCVAD) such as severe systemic PCV2 infection and Post-weaning Multisystemic Wasting Syndrome (PMWS), PCV2-associated pneumonia as part of the Porcine Respiratory Disease Complex (PRDC), PCV2-associated enteritis, PCV2-associated reproductive failure, and Porcine Dermatitis and Nephropathy Syndrome (PDNS). The symptoms of PCVAD develop slowly and progressively, and are often fatal, causing significant economic losses to pig producers worldwide. Vaccines are currently available to pig farms as a prevention measure.

ViPrimePLUS Porcine Circovirus 2 qPCR Kit is intended for research use only.

Kit Component

  • PCV2 Primers and Probe Mix (PCV2 PPM)
  • Positive Control
  • Internal Extraction Control Primers and Probe Mix (IEC PPM)
  • Internal Extraction Control (IEC DNA)
  • Nuclease Free Water
  • Template Preparation Buffer

Product Specification

Technology Taqman probe-based real-time PCR assay
Type of Nucleic Acid Kit RNA
Kit Storage Shipped in room temperature, store at -20℃ on arrival
Sample Material Porcine samples (blood, tissues)
Gene Target 3’ non coding region (3’NCR).
Detection Limit 10 to <100 copies per reaction
Sensitivity & Specificity Ct value 28±3 with probability of 95%
Controls Included • Internal Extraction Control (IEC) as inhibition control
• Positive control
Channels • FAM channels detect pathogen amplicons
• VIC/HEX channel detects IEC amplicons

Ordering Information

Catalog No Description Pack Size
QV5003 ViPrimePLUS Porcine Circovirus 2 qPCR Kit 150 reactions

Download
Manual

ViPrimePLUS Porcine Circovirus 2 qPCR Kit

 

DOWNLOAD & RESOURCES

Brochure
MSDS
Video
Promotion

 

ADDITIONAL INFORMATION

ISO Certificate
RE Buffers Activity Chart

Reaching Us

Headquarters

Vivantis Technologies Sdn Bhd

Revongen Corporation Center,

Level 17, Top Glove Tower,

No. 16, Persiaran Setia Dagang,

Setia Alam, Seksyen U13,

40170 Shah Alam,

Selangor Darul Ehsan,

Malaysia.


Tel: +603-3359 1166

Fax: +603-3358 0303

 

 

ACCOLADES & ACCREDITATION

Acquaint Us

International Distribution/OEM services:

Email: international@vivantechnologies.com

WhatsApp: +6012 793 0184


Local Distribution/Sales Inquiries:

Email: info@vivantechnologies.com

WhatsApp: +6016 216 0492


Product Technical Support:

vivalab@vivantechnologies.com


General Enquiries:

info@vivantechnologies.com

 

SOCIAL MEDIA